• Medical ICU Syringe Injection Pump
  • Medical ICU Syringe Injection Pump
  • Medical ICU Syringe Injection Pump
  • Medical ICU Syringe Injection Pump
  • Medical ICU Syringe Injection Pump
  • Medical ICU Syringe Injection Pump

Medical ICU Syringe Injection Pump

Transport Package: 1 Piece in a Carton
Specification: 320mm× 200 mm× 110mm
Trademark: customized
Origin: China
Diamond Member Since 2019

Suppliers with verified business licenses

Basic Info.

Model NO.
MS-S300
HS Code
9018193010
Production Capacity
1000PCS/Year

Product Description

Medical ICU Syringe Injection PumpMedical ICU Syringe Injection PumpMedical ICU Syringe Injection PumpMedical ICU Syringe Injection PumpMedical ICU Syringe Injection PumpMedical ICU Syringe Injection PumpMedical ICU Syringe Injection PumpMedical ICU Syringe Injection Pump

MS-S300 Syringe Pump

Medical ICU Syringe Injection Pump
Medical ICU Syringe Injection Pump

Characters:

1.     3.5' LCD

2.     rate mode,time mode, Weight Mode,MTIVA Mode, Intdelivery Mode

3.     Compatible with 5ml/10ml/20ml/30ml/50ml standard syringes as open system

4.     Drug library(optional )

5.     Accuracy ±2%(After syringe correct calibration)

6.     flow rate  0.1-1800ml/h

7.     KVO Rate 0.1-1ml/h

8.     2000 history records storage

9.     Stackable function(1  channel to 10 channels)

10.   multi audible and visible alarms system

11.   Operating for more than 6 hours after full charged at 5ml/h

12.   nurse call system(without)

13.   wireless monitoring system(without)


 

Max. injection rate

1500ml/h(Different injectors have different maximum rate.)

Accumulated volume

0.1ml~999.9ml

Max. size of outer shell

320mm×200 mm×110mm (length×width×height)

Injection accuracy

±3% ( up to +1% after calibration.)

Applicable injectors

5ml, 10ml, 20ml, 30ml, 50ml

Injection increment

0.1ml/h

Battery

AC 100~240V,50/60Hz

Volume limit

0.1ml~999.9ml

Battery recharge

Rechargeable Lithium Polymer battery, 7.4V, 1600mA

Classification

ClassII, Type BF

Max. power consumption

Single-channel works for continuous 5 hours at the rate of 25ml/h after fully recharged; double-channel works for continuous 3 hours at the rate of 25ml/h after fully recharged.

Range of flow rate

5ml injector: 0.1ml/h~100ml/h 10ml injector: 0.1ml/h~200ml/h

20ml injector: 0.1ml/h~400ml/h 30ml injector: 0.1ml/h~600ml/h

50ml injector: 0.1ml/h~1500ml/h

Bolus rate

5ml injector: 100ml/h 10ml injector: 200ml/h

20ml injector: 400ml/h 30ml injector: 400~600ml/h (adjustable)

50ml injector: 400~1500ml/h(adjustable)

Alarm information

Near completion, completion, OCCL., injector off, low voltage, No AC Power supply, communication error, link abnormal, pump stuck, reading error of the parameters, etc.

Mode selection

1. Rate mode 2. Time mode 3. Body Weight mode 4. Link mode

Rate mode

Rate: 0.1ml/h~1500.0ml/h(Max. value depends on injector specification)

Time mode

Volume: 0.1ml~999.9ml Time: 1min.~2000 min.

Body Weight mode

Weight: 0.1kg~300.0kg drug: 0.1mg~999.9mg volume: 0.1ml~999.9ml

Dose: 0.1~1500.0 (restricted to unit, drug, solution, weight and injector)

Unit: mg/kg/h, ug/kg/min

OCCL. value

40Kpa~160Kpa,display the voltage status and the pressure value.

KVO rate

Adjustable range: 0.1ml/h~5.0ml/h(adjustable: 0.1ml/h per each segment,press "0" to cancel KVO function.)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2019

Suppliers with verified business licenses

Number of Employees
14
Year of Establishment
2014-02-25
Management System Certification
ISO 9001, ISO 9000, ISO 13485, WRAP