MS-600G Anesthesia Machine
Special Feature:
*5.5"SNT screen,two vaveforms are showed at the same time
*Aluminium alloy frame,durable and elegant
*Double vaporizer station,selectatec compatible
*Independent anesthesia ventilator,could be driven by medical air
*Classical flowmeter of 4 tubes,with O2/N2O linkage device
*Linear Design,could be easily upgraded with functions:eg Adding Multi-Parameter Monitor,CO2 Monitor,AMIS System
*Wrking Mode:Semi~Open,Semi~Closed or Closed System
*Gas Supply Pressure:O2:0.27Mpa~0.55Mpa;N2O:0.27Mpa~0.55Mpa
*Flow Meter:
4Tube:2xO2 Tube,2xN2O Tube;
O2 Tube:0L/min~1L/min~10L/min,
N2O Tube: 0L/min~1L/min~10L/min
O2 and N2O linkage device,keep oxygen concentration not lower than 25%
*Oxygen Flush:25L/min~75L/min
Safety Function:
*When airway pressure reach 6kPa,APL valve will automatically release gas
*When airway pressure reach 6kPa,the Bellows will stop sending gas to patient
*Monitoring parameters(Under Manual and Ventilation):
·Tidal Volume ·Minute Ventilation·Airway Pressure ·Respiration mode·FiO2(Optional)
*Alarm Parameters(Audible and/or visual signal):
·Airway pressure high/low limit
·FiO2 high/low limit
·Low O2 Supply Pressure(when O2 Supply Pressure is over 0.15Mpa,will arouse audio alarm)
·N2O automatic cutoff Alarm
Anesthesia Ventilator:
*Patient Type:Adult,Pediatric
*Driven Mode:Pneumatically driven and Electronically Controlled
*Respiration mode:IPPV,SIMV,SIGN,MANUAL
*Tidal Volume:50~1600ml
*Respiratory Frequency 1~65bpm
*I:E Ratio:8:1~1:8
*Pressure Setting:1~60cmH2O
*Waveforms(Under manual and Ventilation):P-t,V-t
*Mains:100~240V,50/60Hz
*Battery:12V DC,Minimum 120 min.(If with)
*Power consumption≤50W
Circle Absorber:
*Upgraded Intergrated Circle Absorber,with twin large volume CO2 canister,high CO2 absorbing efficiency
·With non-return respiratory valve and expiratiory valve on it,avoid gas back flowing.
·With APL valve on it,the airway pressure could be adjusted freely.
·With "Manual/Ventilation"switch on it,easily and quickly change
Anesthesia Vaporizer:
*The agent output is continous,stable and precise
*Automatic compensation for temperature,flow and pressure
*Flow range:0.2~15L/min
*Temperature Range:Operating 15~35ºC
*Agent:Halothane,Enflurane,Isoflurane,Servofluane for choice
Opitonal:
Yoke Device,Patient Monitor,CO2 Monitor AMIS,AGSS,FiO2