(MS-S200D) Medical Equipment Air Compressor Hospital Surgery ICU Ventilator

Type: Ventilator
Parts: Mobile 1PC Humidifier 1 PC Breath Circuit 1 PC Man
Certification: CE, FDA, ISO13485
Group: Adult
LCD Display: with LCD Display
Anesthesia: None
Diamond Member Since 2019

Suppliers with verified business licenses

Basic Info.

Model NO.
MS-S200D
Source
None
Type of Operating Light
None
Kind
Surgery
Transport Package
1 PC in Carton
Specification
390*310*640mm
Trademark
customized
Origin
China
HS Code
9018193010
Production Capacity
1000PCS/Year

Product Description


(MS-S200D) Medical Equipment Air Compressor Hospital Surgery ICU Ventilator

MS-S200D Ventilator

Physical Specifications
Dimensions
Width: 50cm  Depth: 46cm  Height: 110cm    Weight: 15Kg

Environmental Specifications 
Operating Requirements
Storage/Shipping Requirements
Temperature: 5 to 40ºC
Temperature: -20 to 70ºC
Relative Humidity: less than 80%
Relative Humidity: less than 93% 
The atmosphere pressure: 70 to 106 kPa
The atmosphere pressure: 70 to 106 kPa

Electrical Specifications And Fuse Specification Information 
Input Voltage Requirements
Fuse Quantity: 2
AC Voltage: 220V±10%  50HZ±2%
Current Rating: 0.8 A
Power: 170 VA 
Voltage Rating: 250 Volts
Battery:>8h
Type: 5*20 mm RT

Output Voltage Specification Information
AC Voltage: 220V+/-10%
Frequency: 50HZ+/-2%
Power: 130VA

Pneumatic Specifications
Oxygen Inlet
Pressurized Oxygen: 0.28~0.6 MPa medical oxygen

IEC Classification
Ordinary equipment, not protected against the ingress of liquids Not protected/Not suitable for use in the presence of flammable anesthetic gases
Class I, Type B

Performance Specification
Controls
Power: ON/OFF
Modes: IPPV(C) IPPV+SIGH SIPPV(A/C)   SIMV  MANUAL
Tidal Volume: 50~1200ml
Breath Rate: 5~60 bpm
PEEP:0~20hPa
%O2: 45~97%
Sigh:1~10 per 100 breath
Inspiratory Time: 0.5~3sec
Trigger Level:-10~0hpa
Over Pressure Relief: less than 60hpa 

Alarms and Indicators
High Pressure Alarm Limit:flash, red indicator, can be adjustable
Low Pressure Alarm Limit: Red indicator , can be adjustable
High Minute Volume Alarm Limit: flash, Red indicator, can be adjustable
Low Minute Volume Alarm Limit: flash, Red indicator, can be adjustable
High Rate Alarm Limit: flash, Red indicator, can be adjustable
Apnea interval: 15, 30, 45, 60second     flash, Red indicator
Alarm Silence: 120sec. max
Power: Red indicator
Insp. Phase: Green indicator
Exh. Phase: Green indicator
T.VOL Indicator: Green indicator
MIN. VOL Indicator: Green indicator
PRESSURE Indicator: Green indicator 
RATE Indicator: Green indicator

Monitors and Wave Display
Tidal Volume
MIN. Volume 
Total Breath Rate
Main Circuit Pressure

Packing List
Ventilator 1pc
Mobile 1pc
Humidifier 1 pc
Breath Circuit 1 pc
Manipulators 1 pc
Oxygen Pressure Reducer 1 pc
Mask 1 pc
Lung Simulators 1 pc
Hand Book 1 pc
CD For Operation 1 pc

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2019

Suppliers with verified business licenses

Number of Employees
14
Year of Establishment
2014-02-25
Management System Certification
ISO 9001, ISO 9000, ISO 13485, WRAP