(MS-380C) First Aid Portable Biophasic Defibrillator Monophasic Aed Defibrillator

Type: Defibrillator
Kind: Gynaecology
Certification: CE, FDA, ISO13485
Group: Adult
LCD Display: With LCD Display
G.W: 1.2 Kg
Diamond Member Since 2019

Suppliers with verified business licenses

Basic Info.

Model NO.
MS-380C
N.W
0.9 Kg
Transport Package
1 Piece in Carton
Specification
390*310*640mm
Trademark
customized
Origin
China
HS Code
9018193010
Production Capacity
1000PCS/Year

Product Description

(MS-380C) First Aid Portable Biophasic Defibrillator Monophasic Aed Defibrillator

 

MS-380C Biophasic Defibrillator

 

Physical characteristics:

Main unit: Portable

Dimensions:L320xW205xH410

Weight:9.8kg

Technical specifications

 

Defibrillator:

(1) Defibrillator type Manual, Synchronized, Asynchronized,

(2) Out put waveform Biphasic technology

(3) Energy accuracy ∠+1%

(4) Energy selection 0,3,5,7,10,20,30,50,100,200,300,360 joule(normal at a resistance of 50)

(5) Charging time Maximum 8 seconds to 360 Joules

(6) Standard Adult/Pediatric Paddles Reusable extermal adult paddles(pediatric paddles integrated)

 

Power requirements

(a) AC Power supply 110V, 60 Hz /220V,50 Hz

(b) Vehicle Voltage DC 12V

 

Internal Battery Backup

(1) Battery type Rechargeable lithium battery

(2) Charging time Time-Minimum of 4 hours for full charging

(3) Battery charging During AC Power Supply operation of the device.

(4) Charging /Low Battery Indication Red LED

(5) Battery Capacity 100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules.

 

Display

-LED Dimensions 7'diagonal {155mm*88mm}

-Type High resolution true-color graphic LED

-Resolution 480X234

 

ECG

ECG lead: I, II, III, AVR, AVL, AVF, V1~V6, GND 
S-T segment analysis: -2.0~2.0mv 
Arrhythmia analysis: yes 
Protegtion: With stand 4000vAc/50Hz voltage in isolation and work against eletrosurgical interence and defibrillation

 

Respiration

Measurement method: Thoracic impedance

 

NIBP

Working mode: Manual/Automatic/stat(5 minutes) 
Method: Automatic oscillation 
Cufftype: standard Adult; optional Pediatric/Neonatal

 

Temperature

Measurement range 20~45ºC

Resolution 0.1ºC

 

Pulse Oximetry(spO2)

Display :spo2 value,pulse histongram,waveform,Pulse

Range: 0~99%for adult,pediatric and neonatal patients

Probe :standard adult finger clip

optional pediatric Y-type clip and neonatal wrap

 

Pulse range 
Pulse range: 0-255bpm

 

Standard parameter & configuration

ECG/ RESP,/SPO2,/TEMP,/PR,/NIBP/DEFIBRILLATOR

Optional parameter

Recorder

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2019

Suppliers with verified business licenses

Number of Employees
14
Year of Establishment
2014-02-25
Management System Certification