Ms-S400A Baby Ventilator Neonatal Portative Emergency Ventilators

Product Details
Type: Ventilator
G.W: 22 Kg
N.W: 18 Kg
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
14
Year of Establishment
2014-02-25
Management System Certification
ISO 9001, ISO 9000, ISO 13485, WRAP
  • Ms-S400A Baby Ventilator Neonatal Portative Emergency Ventilators
  • Ms-S400A Baby Ventilator Neonatal Portative Emergency Ventilators
  • Ms-S400A Baby Ventilator Neonatal Portative Emergency Ventilators
  • Ms-S400A Baby Ventilator Neonatal Portative Emergency Ventilators
  • Ms-S400A Baby Ventilator Neonatal Portative Emergency Ventilators
  • Ms-S400A Baby Ventilator Neonatal Portative Emergency Ventilators
Find Similar Products

Basic Info.

Model NO.
MS-S400A
Certification
CE, FDA, ISO13485
Group
Adult
LCD Display
with LCD Display
Source
Air
Anesthesia
Semi Closed
Type of Operating Light
Double Operating Light
Kind
Surgery
Transport Package
1 Piece in Carton
Specification
390*310*640mm
Trademark
customized
Origin
China
HS Code
9018193010
Production Capacity
1000PCS/Year

Product Description

Ms-S400A Baby Ventilator Neonatal Portative Emergency VentilatorsMs-S400A Baby Ventilator Neonatal Portative Emergency VentilatorsMs-S400A Baby Ventilator Neonatal Portative Emergency VentilatorsMs-S400A Baby Ventilator Neonatal Portative Emergency VentilatorsMs-S400A Baby Ventilator Neonatal Portative Emergency VentilatorsMs-S400A Baby Ventilator Neonatal Portative Emergency Ventilators
MS-S400A Medical
Neonatal Ventilator


Characters:
Patient Type: Adult, Pediatric& Neonatal Patients
Dimension(HXWXD):130cm X68cm X 60cm
Weight :78kgs
Power:220V/50Hz,110V/60Hz
Backup Power:At least 30 minutes,nominally between 2 to 4 hours
Display:10.4 Inch TFT display

Specifications
Ventilator:
Tidal Volume:Adjustable range:20-1500 ml,Display Range:0-2000 ml.
Respiratory Rate:1-99 bpm
Inspiratory Pressure Limit:5-70cm H2O
Ventilatori Modes:
Manual, Spontaneous, Assist/Ctontrol(A/C), Intermittent Positive Pressure Ventilatiron(IPPV), Synchronized Intermittent Positive Pressure Ventilatiron(SIPPV), Volume Controlled Ventilation(VCV), Synchronized Intermittent Mandatory Ventilation(SIMV), Pressure Synchronized Intermittent Mandatory Ventilation(P-SIMV), Pressure Control Ventilation(PCV), Pressure Support Ventilation(PSV), Continuous Positive Airway Pressure(CPAP)
Minute Volume:≥18L/min BTPS
Trigger Sensitivity:Pressure:-10~10cm H2O
SIMV Rate:1-20 bpm
Inspiration/Expiration Ratio(I:E)4:1-1:4
Inspiratory Time:0.1-2.0s
PEEP:0-10cm H2O
PSV:3-40 cm H2O
Oxygen&Air Inlet Pressure Range:280-600kPa
O2 Concentration 21-100%
SIGH:1-8 per 100 breaths(Tidal Volume set 1.5X)

Aircompressor&Humidifier:
Humidifier:9 Level Adjustable Nebulization
Compressor Power: 220V/50Hz,110V/60Hz
Compressor Gas Pressure: 0.3-0.5Mpa
Output Gas Flow:Continuous:≥20L/Min, Instantaneous:≥60L/min

Momintoring:
Tidal Volume, Inspirateion Tidal Volume,Expiration Tidal Volume, Minute Volume, Control Frequency, Spontaneous Respiration Rate, Airway Pressure, I:E inhalation&exhalation Status, Inspiratory Trigger,Ihaled Oxygen Concentration, PEEP, Airway Resistance, Lung Compliance

Alarm
Audible/Visual Alarms for Intubation Disconnection, Tidal Volume, Ventilaton Volume, Oxygen Concnetration, asphyxia,Airway Pressure, Low Oxygen, Power Failure, Alarm Query Function.


 

 