Type: | Infant Radiant Warmer |
---|---|
Kind: | Pediatrics |
Certification: | CE, FDA, ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MS-W500A Infant Radiant Warmer
Brief introduction:
* Micropro cessor based servo controlled temperature
* Alarm functions for safety includes:
Power failure;
Temperature deviation;
Temperature sensor failure;
Over temperature;
* Transparent protetor
* Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source,the heating is quick and life-span is long.
* Alarms are audible and visual
* A second thermal cut-out function for more safety
* Skin temperature sensor failure protect function avoid over stemperature
Standard configuration:
Main body (including the radiant source, control system, infant bed, bracket), I.V.pole, skin temperature sensor, tray, mattress, transparent protector, castors.
Technical data:
1. Power supply: 110/220V 60/50Hz
2. Power input: ≤1200VA
3. Operating condition:
An ambient Temperature:18°C -30°C
An ambient Relative Humidity: 30%--75%RH
Atmospheric Pressure: 700~ 1060 hPa
An ambient Air Velocity :< 0.3m/s
4. Temperature control: 32°C ~ 38°C
5.Temperature control accuracy: ≤0.5°C
6.Mattress temperature uniformity : < 2°C
7.Skin temperature sensor accuracy: + 0.3°C
8.Warm-up time: ≤30min
9.Mattress size: 67cm× 54 cm
10.Distance from heater to mattress: 80cm
Transport and storage:
Environment Temperature:-40°C ~ +55°C
Environment Relative Humidity: ≤95%
Atmospheric Pressure: 500~1060hPa
Package:
Each unit is packed one case
Size:110cm× 78cm × 86cm
Gross weight: ≤90Kg