Ms-8600 Multi-Parameter Patient Monitor

Product Details
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: CE, FDA, ISO13485
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
14
Year of Establishment
2014-02-25
Management System Certification
ISO 9001, ISO 9000, ISO 13485, WRAP
  • Ms-8600 Multi-Parameter Patient Monitor
  • Ms-8600 Multi-Parameter Patient Monitor
  • Ms-8600 Multi-Parameter Patient Monitor
  • Ms-8600 Multi-Parameter Patient Monitor
  • Ms-8600 Multi-Parameter Patient Monitor
Find Similar Products

Basic Info.

Model NO.
ms-8600
Group
Middle-aged and Old
Transport Package
Carton on Pallet
Trademark
customized
Origin
China
HS Code
9018193010
Production Capacity
100, 000, 00 PCS/Year

Product Description

Ms-8600 Multi-Parameter Patient Monitor
Ms-8600 Multi-Parameter Patient Monitor


Ms-8600 Multi-Parameter Patient Monitor
Ms-8600 Multi-Parameter Patient Monitor
Ms-8600 Multi-Parameter Patient Monitor
 

MS-8600 Multi-Parameter Patient Monitor

Features: 
12″ color TFT-LCD touch screen 
Suitable for adult, pediatric and neonatal patient  
Audible and visual alarms with adjustable alarm ranges 
Powerful data management and storage capacity 
 
ECG 
Lead type:5-lead 
Input: RA; LA; RL; LL; V 
Sweep speed: 12.5mm/s, 25mm/s, 50mm/s 
Accuracy: ±1bpm or ±1%, whichever is greater 
Protection: Withstand 4000VAC/50Hz voltage in  isolation against electrosurgical and defibrillation 
S-T detection: YES, Arrhythmia analysis: YES 
Alarm: YES, audible and visual alarm, alarm events recallable 
 
NIBP 
Method: Oscillometry
Operation modes: Manual/Automatic/STAT
Measurement unit: mmHg/KPa selectable 
Measurement types: Systolic, Diastolic, Mean 
Over-pressure protection: YES

SpO2
Measurement range: 0-100% 
Accuracy: ±2digit (70~100%);
0~69% unspecified

Respiration
Method: RA-LL impedance 
Pediatric/Neonatal: 6-150rpm
Alarm range: Adult: 6-120rpm
Pediatric/Neonatal: 6-150rpm 
Apnea alarm: YES

Temperature 
Resolution: 0.1ºC
Channel: Dual-channel 
Alarm range: 0-50ºC

Option: 
EtCO2 
Measurement Mode: Side-stream or mainstream 
Measurement range: EtCO2: 0-99mmHg
Accuracy: CO2 concentration 
Apnea alarm: YES 
 
IBP 
Channel: 2 channels 
Pressure transducer: Sensitivity: 5( mV/V/mmHg) 
Transducer sites: ART, PA, CVP, RAP, LAP, ICP 
Alarm range: -10~300mmHg

Standard Configuration: 
ECG, NIBP,  SpO2,  RESP,2-TEMP,Network

Optional: 
2-IBP,ETCO2,Thermal Recorder

 