(MS-1900) 2.8 Inch Screen Multi-Parameter Portable Vital Signs Monitor

Product Details
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: CE, EEC, MSDS, ISO13485
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
14
Year of Establishment
2014-02-25
Management System Certification
ISO 9001, ISO 9000, ISO 13485, WRAP
Find Similar Products

Basic Info.

Model NO.
MS-1900
Group
Middle-aged and Old
G.W
2.5 Kg
N.W
1.5 Kg
Transport Package
1 PCS in Carton
Specification
390*310*640mm
Trademark
customized
Origin
China
HS Code
9018193010
Production Capacity
10000PCS/Year

Product Description

(MS-1900) 2.8 Inch Screen Multi-Parameter Portable Vital Signs Monitor

MS-1900 Vital Signs Monitor

Features:
•Suitable for adult, pediatric and neonatal patient
•Built-in memory, store up to 100 hours of tabular of patient SpO2
•High brightness cold cathode fluorescent backlight LCD +LED display
•Advanced digital processing technology providing accurate measurement during low perfusion and movement situation
•Adjustable audible and visual alarms
•Built-in large capacity rechargeable lithium battery

Specifications:
Dimension and Weight
-        Dimension: 285mm*230mm*100mm      Weight: 1.7kg(excluding accessories)
Power Supply
-        Voltage: AC100~240V, 50/60HZ
Display
-        LED + LCD       LCD Size: 85mm * 30mm
Battery 
-        Type: Rechargeable lithium battery 3.7V, 2200mAH
-        Working time: 8 hours for continuous working
Alarm
-        Level: Low, medium and high      Indication: Auditory and visual
Operating Environment
-        Temperature:  5 ~ 40 ºC
-        Humidity:  15% ~ 80% (non-condensing)
-        Atmosphere pressure:  86 KPa ~ 110 KPa
Transportation and Storage Environment
-        Temperature:  -20~50 ºC
-        Humidity:  10%~90%  (non-condensing)
-        Atmosphere pressure:  86 KPa ~ 110 KPa
Safety
-        IEC60601-1 Approved, CE marking according to MDD93/42/EEC
-        With reference to RoHS Directive 2011/65/EU recasting
Trend & Reviewing
-        Trend: 100 hours
NIBP
-        Method: Oscillometric
-        Measure mode: Manual, Auto, STAT
-        Measure Interval in AUTO Mode:  1,2,3,4,5,10,15,30,60,90,120,180,240 min
-        STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
-        Measure and Alarm Range:
Adult:          SYS:  30 ~ 270 mmHg
             DIA:  10 ~ 220 mmHg    
             MEAN:  20 ~ 235 mmHg
Pediatric:     SYS:  40 ~ 235 mmHg
DIA:  10 ~ 220 mmHg    
MEAN:  20 ~ 225 mmHg
Neonate:         SYS:  30 ~ 135 mmHg
DIA:  10 ~ 110 mmHg    
MEAN:  20 ~ 125 mmHg
-        Static pressure accuracy: ±3mmHg
-        Resolution: 1mmHg
-        Accuracy: Maximum Mean error ±5mmHg          
     Maximum Standard deviation ≤8mmHg
-        Over pressure Protection: Dual protection via software & hardware
SpO2 (Digital Technic)
-        Measurement Range: 0 ~ 100 %              Resolution: 1 %
-        Accuracy:  ±2% (70% ~ 100%)
               ±3 % (35% ~ 69%)
Unspecified (0 ~ 34%)
Pulse Rate
-        Measuring and Alarm Range: 0~250bpm
-        Accuracy: ±1% or ±1 bpm, whichever is greater
-        Resolution: 1bpm
Nellcor-SpO2 (Option)
-        Measurement Range: 0 ~ 100 %
-        Resolution: 1 %
-        Accuracy:   70% ~ 100%, ±2 % (adult)
                70% ~ 100%, ±3 % (Neonate)
               70% ~ 100%, ±2 % (Low Perfusion)
               0% ~ 69%, unspecified
Pulse Rate
-Measurement range: 20 ~ 300 bpm           Resolution: 1bpm
-Accuracy:  ±3 bpm (20 ~ 250 bpm)     Unspecified (251~300 bpm)

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now