• Portable Digital 6 Six Channel Electrocardiograph ECG
  • Portable Digital 6 Six Channel Electrocardiograph ECG
  • Portable Digital 6 Six Channel Electrocardiograph ECG
  • Portable Digital 6 Six Channel Electrocardiograph ECG
  • Portable Digital 6 Six Channel Electrocardiograph ECG
  • Portable Digital 6 Six Channel Electrocardiograph ECG

Portable Digital 6 Six Channel Electrocardiograph ECG

Classification: Imaging Diagnostic Equipment
Type: ECG
Certification: CE, FDA, EEC, MSDS, ISO13485
Group: Middle-aged and Old
G.W: 4.5 Kg
N.W: 2.5 Kg
Diamond Member Since 2019

Suppliers with verified business licenses

Basic Info.

Model NO.
MS-1260
Transport Package
1 Piece in Carton
Specification
390*310*640mm
Trademark
customized
Origin
China
HS Code
9018193010
Production Capacity
1000PCS/Year

Product Description

Portable Digital 6 Six Channel Electrocardiograph ECGPortable Digital 6 Six Channel Electrocardiograph ECGPortable Digital 6 Six Channel Electrocardiograph ECGPortable Digital 6 Six Channel Electrocardiograph ECGPortable Digital 6 Six Channel Electrocardiograph ECG
Portable Digital 6 Six Channel Electrocardiograph ECG
MS-1260 Six Channel ECG Machine


Features:
  1. 7 inch high resolution color touch screen
  2. 12-lead simultaneous acquisition and display
  3. ECG Automatic measurement and interpretation function
  4. Complete digital filters, resisting baseline drift, AC and EMG interference
  5. Compact and lightweight design
  6. Support USB flash disk and micro SD card to extend memory
  7. Software upgrade via USB/SD card
  8. Built-in rechargeable Li-ion battery
  9.  
Technical Specifications:
Items Specification
Lead Standard 12 leads
Acquisition Mode Simultaneous 12 leads acquisition
Measurement Range ±5mVpp
Input circuit Floating; Protection circuit against Defibrillator effect
Input Impedance ≥50MΩ
Input circuit current <0.05µA
Record mode Automatic: 3CH×4+1R, 3CH×4, 3CHx2+2CHx3,3CHx2+2CHx3+1R,6CHX2;
Manual: 3CH, 2CH, 3CH+1R, 2CH+1R;
Rhythm: Any lead selectable.
Filter EMG Filter: 25 Hz / 30 Hz / 40Hz/75 Hz / 100 Hz / 150Hz
DFT Filter: 0.05 Hz/ 0.15 Hz
AC Filter: 50 Hz / 60Hz
CMRR  >100dB
Patient leak current <10µA (220V-240V)
Frequency Response 0.05Hz~150Hz (-3dB)
Sensitivity 2.5mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mV (error:±5%)
Anti-baseline Drift Automatic
Time constant ≥3.2s
Noise level <15µVp-p
Paper speed 12.5 mm/s, 25 mm/s, 50 mm/s
Recording mode Thermal printing system
Paper specification Roll 110mmx20M
Safety Standard IEC I/CF
Sample Rate Normal: 1000sps/channel
Power Supply AC: 100~240V, 50/60Hz, 30VA~100VA
DC: 14.8V/2200mAh, built-in lithium battery

Standard Configuration:
  1. Main machine:  1 PC
  2. Patient cable: 1 PC
  3. Limb electrode:  1set (4pcs)
  4. Chest electrode: 1set( 6pcs)
  5. Power cable:  1 PC
  6. 110mm*20M recording paper: 1 PC
  7. Paper axis: 1 PC
  8. Power cord: 1 PC
Packing:
  1. Single package size: 32*25*17cm
  2. Single gross weight: 2.8 KG
  3. 8 unit per carton, package size: 54*33*75cm, total gross weight 22 KG

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2019

Suppliers with verified business licenses

Number of Employees
14
Year of Establishment
2014-02-25
Management System Certification
ISO 9001, ISO 9000, ISO 13485, WRAP