• (MS-8700) 12.1′color Touch Screen Multi-Parameter Etco2 SpO2 Patient Monitor
  • (MS-8700) 12.1′color Touch Screen Multi-Parameter Etco2 SpO2 Patient Monitor

(MS-8700) 12.1′color Touch Screen Multi-Parameter Etco2 SpO2 Patient Monitor

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: CE, FDA, ISO13485
Group: Middle-aged and Old
Medical Device Regulatory Type: Type 2
Transport Package: Carton on Pallet
Diamond Member Since 2019

Suppliers with verified business licenses

Basic Info.

Model NO.
MS-8700
Trademark
customized
Origin
China
HS Code
9018193010
Production Capacity
100, 000, 00 PCS/Year

Product Description

(MS-8700) 12.1′color Touch Screen Multi-Parameter Etco2 SpO2 Patient Monitor
(MS-8700) 12.1′color Touch Screen Multi-Parameter Etco2 SpO2 Patient Monitor
MS-8700 Multi-Parameters Patient Monitor
8 Inch
Basic: 5 leads ECG, SPO2, NIBP , 1-Temp, HR/PR
Options: Touch, EtCO2 ( mainsteam / sidestream), Printer, 2IBP, Masimo SPo2, CMS

Features:
Standard anti-shock class         : class I
EMC type:                                class A 
Standard anti-shock level         
CF level for ECG(RESP); type BF for SpO2,NIBP; TEMP
Anti-entering fluid level:
common seal apparatus, does not have the function to prevent liquid entering
Disinfection / sterilization methods: 
details as per chapter 5
Working method:   Continuous

Sepcifications:
Working condition
TEMP range Working:0 ~ 40 °C
transportation and storage:-20 ~ 60 °C
Humidity:≤85 %
transportation and storage         ≤93%
Altitude Range:-500 - 4,600m(-1,600 - 15,000feet)
transportation and storage:-500 - 13,100m(-1,600 - 43,000feet)
Electric specification:100~250 VAC, 50/60 Hz, Maximum 70VA

Displaying Info
Maximum 6 waveforms
One alarm light (yellow/red)
One working indictor(green)
One battery charging indictor(yellow)
Three corresponding sound alarming mode
Battery
14.8V/4400mAhLi-ion rechargeable battery
Under normal working condition, battery works for 100 minutes
It can works for 5 minutes after the first time power alarm
Maximum 8 hours charging time

Recorder
Paper's width:48mm
Printing speed:25 mm/S
Scanning waveform:2 channels
Recording type:8 seconds real time recording

Recall
Short trend
1 hour, resolution: 1 second or 5 second
Long trend
72hours ,resolution 1 minute,5minutes or10minutes
NIBP measurement recall     400 pcs NIBP measured value's recall

ECG Specification
Lead configuration
Standard 3 lead or 5 lead cable
3 lead                           RA,LA,LL,lead method:I,II,III
5-lead                           RA,LA,LL,RL,V,lead method:I,II,III,aVR,aVL,aVF,V
Gain ´0.25,´0.5,´1,´2,auto
Heart Rate
Range
Adult                     15 ~ 300bpm (beat/min)
Neonate/pediatric        15 ~ 350 bpm(beat/min)
Accuracy                        ±1% or ±1bpm,choose the bigger one
Resolution                   1 bpm(beat/min)
Sensitivity > 200 µV (peak-peak date )
Impedance> 5 (Megohm)
Bandwidth
Diagnostic mode          0.05~130Hz
Monitoring mode             0.5~40Hz
Operation mode               1~20Hz
Common-mode rejection ratio
Diagnostic mode          > 90 dB
Monitoring mode            > 100 dB
Operation mode               > 100 dB
Electrode polarization voltage range ±300mV
Pacemaker pulse detection
It can test the following pace-maker pulse :
Extent :                ±2 mV ~ ±700mV
width:                   0.1ms ~ 2ms
Rise time :          10µs~100µs
Pacing pulse suppression
When the pacing analysis switch is on, it can suppress pacing pulse within the following condition and will not affect the calculation of heart rate:
Extent:              ±2 mV ~ ±700mV
Width:              0.1ms ~ 2ms
Rise time :      10µs ~ 100µs
Recovery time of base line
After Defibrillation< 3 second
Signal's range ±8 mV (peak value )
Calibration signal :1mV (peak value ),accuracy      ±5%
ST measurement
Range:              -2.5mV ~ +2.5mV
Measurement accuracy:within -0.8 mV~+0.8mV, the tolerance is  ±0.02mVor ±10%
      Without this range, there is no definition

RESP Specification
Measurement
RA-LL Impedance
Detection range of respiratory impedance:0.3~
Base resistance range:200~4000Ω
Bandwidth:0.1~2.5Hz
RESP Rate Range:
Adult                              0~120 BrPM
Pediatric and neonate              0~150 BrPM
Resolution                            1 BrPM
accuracy                                     ±2 BrPM
Suffocation alarm
10~40 seconds


SpO2
SPO2
Range                   0~100%
Resolution   1%
Accuracy      70~100%:±2 DIGIT                                                                        
                    0%~69%: Not defined
pulse rate Measurement Range            20~300bpm
Resolution                           1bpm
accuracy                              ±3bpm
TEMP's specification
TEMP transducers applied
YSI series, CYF series
Channel's quantity :2 channels
Measurement Range           0~50°C
Resolution 0.1°C
Accuracy    ±0.1°C, not include a sensor error

NIBP specification
Measurement
Pulse wave oscillation
Working mode :manual/auto
Interval of auto measurement
1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes
Measurement time of Continuous measurement mode:5 minutes
Pulse rate range:30 ~ 250 bpm
Measuring range and accuracy Range:
ADULT:      
SYS                 40~270mmHg
DIA            10~215mmHg
MEAN                  20~235mmHg
PEDIATRIC:
SYS         40~200mmHg
DIA                 10~150mmHg
MEAN            20~165mmHg
NEONATE: 
SYS       40~135mmHg
DIA             10~100mmHg
MEAN                  20~110mmHg
Static Pressure Range       0~300mmHg
Static Pressure accuracy            ±3mmHg
blood pressure accuracy :          
Maximum average error            ±5mmHg;
Maximum standard deviation        8mmHg
over-pressure protection
Adult mode                    300 mmHg±10 mmHg
Pediatric mode                240 mmHg±10 mmHg
Neonate mode               150 mmHg±10 mmHg
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2019

Suppliers with verified business licenses

Number of Employees
14
Year of Establishment
2014-02-25
Management System Certification
ISO 9001, ISO 9000, ISO 13485, WRAP